Avaya Communication Manager controlled maintenance
DIOD-TRK (DIOD Trunk)
132
Maintenance of the Avaya G350 Media Gateway
June 2004
Error Log Entries and Test to Clear Values
Notes:
•
These are in-line errors that have no specific test associated with them. Refer to the following
Table 71, DIOD Trunk Errors without Associated Tests,
on page 133 for an explanation and
appropriate action.
•
This is a software audit error and does not indicate any hardware malfunction. Run the Short Test
Sequence and investigate associated errors.
•
These errors cause the Dial Tone Test (#0) to run and are only considered a problem if the Dial
Tone Test fails (in which case Error Type 1537 also appears). In this case, the trunk may be put in
‘‘Ready-for-Service’’ state (shown as ‘‘disconnected’’ by status command), which allows only
incoming calls. Run the Dial Tone Test (#0) and follow its procedures.
Aux data 57376
—
No loop current on incoming call
Aux data 57424
—
No loop current on outgoing call
•
Single polarity ringing current
—
This error results from abnormal ringing current, but does not
prevent the incoming call from being accepted. This error code is logged for information purposes
only and does not cause additional testing to occur.
•
Late CO Trunk release
—
This indicates that the CO releases the trunk at least four minutes after
the PBX dropped the call. This error code is only logged as an informational event and causes no
other testing to occur.
Table 70: DIOD Trunk Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear
Value
0*
0
Any
Any
Any
test port sh
15 (b)
any
Port Audit Update
Test (#36)
18
0
Busyout trunk
grp/mbr
WARNING
release trunk
769 (a)
57392
None
MAJ/MIN/WRN**
ON
1537 (f)
2561 (a,d)
57345
None
2817 (a,e)
57393
None
3073 (a,c)
57376
None
3585 (a,c)
57424
None
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
**Major alarms on this MO may be downgraded to Warning alarms based on the value used in the
set options command. If the Minor alarm is not downgraded by the
set-options
values, the Minor
alarm is upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...