Avaya Communication Manager controlled maintenance
AN-LN-PT (Analog Line Port)
82
Maintenance of the Avaya G350 Media Gateway
June 2004
FAIL
The port’s battery feed chip is unable to supply sufficient power to the
terminal equipment. This test result might be marginal, and the terminal
equipment may be operating satisfactorily.
Retry the command at 1-minute intervals no more than 5 times.
If the test continues to fail, determine whether the customer is
experiencing problems on this line. Replace the Media Module only if the
customer is experiencing problems.
PASS
The port’s battery feed chip is able to provide sufficient power to the
station equipment to detect on-/off-hook, but may not be able to supply
power for touch-tones.
If touch-tones are inoperative on this station, replace the Media Module
because this port is inoperative.
Investigate user-reported troubles on this port by running other port tests,
by examining station wiring, or by inspecting the station.
Any
NO
BOARD
The test could not relate the internal ID to the port (no board). This result
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
Check to make sure that the board translations are correct. Use the
list
configuration
command, and resolve any problems.
If the board is correctly inserted, use the
busy board GGGVS
command.
Use the reset board GGGVS command.
Use the release board GGGVS command.
Use the test board GGGVS long command. This re-establishes the link
between the internal ID and the port.
If this is not the case, check to make sure that a valid board is inserted.
Table 37: TEST #35 Battery Feed Test 3 of 3
Error
Code
Test
Result
Description/Recommendation
3 of 3
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...