Avaya Communication Manager controlled maintenance
ISDN-LNK (ISDN-PRI Signaling Link Port)
Maintenance of the Avaya G350 Media Gateway
139
June 2004
Signaling Link Board Check (#643)
This test checks the health of the MM710 Interface transporting the ISDN-PRI Signaling Link Port
Table 77: Test #643 Signaling Link Board Check
Error
Code
Test
Result
Description/ Recommendation
ABORT
Internal System Error
Retry the command at 1-minute intervals for a maximum of 5 times.
If the test continues to abort, escalate the problem.
1700
ABORT
Rollabout video abort. The PRI terminal adapter associated with this D-
channel port is detached from the Media Module. This is normal when
the rollabout video feature is enabled. To complete a test on this port, do
one of the following:
Re-attach the disconnected PRI terminal adapter
Disable the rollabout video feature on this board by entering
change
ds1 GGGVSpp
and set the field labeled “Alarm when PRI Endpoint
Detached?” to “y.”
8
FAIL
The MM710 is not in-service.
Check the Hardware Error Log for entries logged against DS1 MM and
consult the DS1 Interface Media Module Maintenance documentation for
repair procedures.
PASS
The MM-DS1 Interface Media Module transporting the ISDN-PRI
Signaling Link Port is in-service.
Any
NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the
add ds1
GGGVS
command to administer the MG-DS1 interface if it is not
already administered.
If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board
is shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then use the
busyout board
command.
Use the
reset board
command.
Use the
release busy board
command.
Use the
test board long
command.
This should re-establish the linkage between the internal ID and the port.
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...