Avaya Communication Manager controlled maintenance
XXX-BD (Common Port Media Module)
Maintenance of the Avaya G350 Media Gateway
235
June 2004
•
The Media Module physically installed in the slot does not match the type that is administered for
that slot. Do one of the following:
— Remove the incorrect Media Module and replace it with one of the type that is
administered for that slot.
— Use
change media module
to re-administer the slot so that it matches the board that is
installed, and follow with
reset board
.
•
This error indicates transient communication problems with this Media Module. This error is not
service-affecting and no action is required.
•
This error, when reported with Aux data in the range of 4352 to 4358, indicates that the Media
Module has reported an on-board hardware failure. The Media Module will continuously test the
hardware and report the results approximately every 10 minutes. If the hardware problem is
resolved, the “leaky bucket” strategy should clear the alarm in approximately 30 minutes.
However, if the alarm does NOT clear in 30 minutes, then the Media Module should be replaced.
•
This error can be ignored, but look for other errors on this Media Module.
•
This error indicates that no ringing current is detected. Run Test #51, Ringing Application Test,
and follow the procedures for Test #51. This error is only applicable to Analog Line Media
Modules.
•
The hyperactive Media Module is out-of-service and may exhibit one or more of the following
symptoms:
— The common Media Module level tests such as Test #51 are aborting with error code
2000.
— The tests run on the ports of this Media Module are returning with a NO-BOARD.
— A busy-out/release of the Media Module has no affect on test results.
— A
list configuration
command shows that the Media Module and ports are properly
installed.
If this error happens again within 15 minutes, then replace the Media Module. If the XXX-BD is a
Digital Line Media Module, then check the alarm level. If the alarm level is a WARNING, this
indicates that users are probably causing the hyperactivity by playing with their digital stations. If
the Media Module is really hyperactive then this alarm will be upgrade to a MINOR alarm within
1 hour. If the alarm level is a MINOR alarm, then replace the Media Module.
•
This error is not service-affecting and no action is required.
•
Error type 3999 indicates that the Media Module sent a large number of control channel messages
to the switch within a short period of time. If error type 1538 is also present, then the Media
Module was taken out-of-service due to hyperactivity. If error type 1538 is not present, then the
Media Module has not been taken out-of-service, but it has generated 50% of the messages
necessary to be considered hyperactive. This may be completely normal during heavy traffic
periods. However, if this error type is logged when the Media Module is being lightly used, it may
indicate a problem with the Media Module or the equipment attached to it.
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...