Avaya Communication Manager controlled maintenance
DID-DS1 (Direct Inward Dial Trunk)
Maintenance of the Avaya G350 Media Gateway
107
June 2004
Maintenance does not start any testing or generate any alarms in response to these errors.
•
Error Type 15—This is a software audit error that does not indicate any hardware malfunction.
Run Short Test Sequence and investigate errors (if any).
•
Error Type 18—The trunk has been taken out of service by a demand busyout. No calls can be
made on this trunk.
•
Error Type 130—This error type indicates that the Media Module has been removed or has been
insane for more than 11 minutes. To clear the error, reinsert or replace the Media Module.
•
Error Type 257—DS1 Interface Media Module detects a hardware error on the DS1 DID trunk.
The Aux Data field indicate the source of the error:
•
Error Type 513—DS1 Interface Media Module detects a hardware error on the DS1 DID trunk.
Aux Data 57392 indicates no external release on PBX disconnect.
•
Error Type 769—DS1 Interface Media Module detects a hardware error on the DS1 DID trunk.
Aux Data 57393 indicates belated external release on PBX disconnect.
•
Error Type 1793—DS1 Interface Media Module is out-of-service. Look for MG-DS1 errors in
Hardware Error Log. Refer to the appropriate “MG-DS1” information for details.
•
Error Type 2305—This error indicates that a signaling change was detected by the PBX trunk
Media Module which is inconsistent with the present state of the trunk.
•
Error Type 3840—Port Audit and Update Test (#36) failed due to an internal system error. Enter
status trunk
command to verify the status of the trunk. If the trunk is out-of-service, then enter
the
release trunk
command to put it back to in-service. Retry the test command.
System Technician-Demanded Tests:
Descriptions and Error Codes
CAUTION:
Always investigate tests in the order they are presented in the table below. By
clearing error codes associated with the
NPE
Crosstalk Test, for example, you
may also clear errors generated from other tests in the testing sequence.
.
57474
Rotary dial rate above 12 pulses per second
57473
Rotary dial rate below 8 pulses per second
Table 54: Order of Investigation
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND*
NPE Crosstalk Test (#6)
Note
: This test will abort with Error Code 1412
X
ND
Conference Circuit Test (#7)
Note
: This test will abort with Error Code 1412
X
ND
Port Audit and Update Test (#36)
X
X
ND
*D = Destructive; ND = Nondestructive
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...