Avaya Communication Manager controlled maintenance
TIE-DS1 (DS1 Tie Trunk)
Maintenance of the Avaya G350 Media Gateway
221
June 2004
Notes:
•
Error Type 1—The DS1 Interface Media Module detects a hardware error on the DS1 tie trunk.
This error can be caused by incompatible translations. Make sure the parameters administered on
the DS1 Media Module form match those administered on the far-end switch. See Administrator’s
Guide for Avaya Communication Manager, 555-233-506, for details.
The Aux Data field indicates the following hardware error types:
If all administration errors between the switch and the far-end match, and these errors continue to
recur, follow normal escalation procedures.
130(e)
None
WARNING
ON
test trunk grp/mbr
257(f)
57473
57474
513(g)
57392
DS1 Tie Trunk
Seizure Test (#136)
MIN/MAJ
769(h)
57393
DS1 Tie Trunk
Seizure Test (#136)
MIN/MAJ
1025
DS1 Tie Trunk
Seizure (Test #136)
MIN/
WRN***
OFF
test trunk grp/mbr r 2
1793(i)
test board GGGVSpp
long
2305(j)
50944
DS1 Tie Trunk
Seizure Test (#136)
MIN/MAJ
OFF
2562(k)
16665
2817(l)
52992
3840(m)
Any
Port Audit and
Update (Test #36)
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
***This alarm will only be raised when the System-Parameter Country form has the Base Tone
Generator field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in
this trunk group are out of service, then the alarm will be upgraded to a MAJOR alarm.
****Major or Minor alarms on this MO may be downgraded to Warning alarms based on the
values used in the
set options
command.
57476
On-hook before wink
57477
On-hook before ready to receive digits
57485
Wink too short for valid signal
57487
The timer expired while waiting for an off-hook signal
from the far end as a response at end of digits dialing.
Check the far-end switch for related problems.
Table 122: DS1 Tie Trunk Maintenance Error Log Entries 2 of 2
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
2 of 2
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...