Avaya Communication Manager controlled maintenance
TIE-DS1 (DS1 Tie Trunk)
Maintenance of the Avaya G350 Media Gateway
227
June 2004
1020
ABORT
The test did not run due to an already existing error on the specific port
or due to a more general Media Module error.
Examine the error log for existing errors against this port or the Media
Module and attempt to diagnose the already existing error.
Retry the test.
1040
ABORT
The test is invalid for this trunk port because it is administered as an
access endpoint.
Use
display port
to verify that this port is administered as an access
endpoint. In this case the test should abort.
2000
ABORT
Response to the test request was not received within the allowable time
period.
Retry the command at 1-minute intervals for a maximum of 5 times.
2053
ABORT/
FAIL
*
At least one of the following errors is found on the DS1 Media Module:
1281: Loss of Signal 1793: Blue Alarm 2049: Red Alarm 2305: Yellow
Alarm 1537: Hyperactivity
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD/MM-DS1-BD
Maintenance documentation for the listed error types.
2100
ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL
The far-end trunk did not respond to the seizure of the near-end trunk
within the allowable time period. This test could have associated in-line
errors in the error log.
Enter the
list configuration board GGGVS
command. Eventually,
the board and all of its ports will be taken out of service and extraneous
on-board alarms will be generated. Replace the Media Module with a
TN767C V3 or later.
Verify that the ’Trunk Type’ field on the ’Trunk Administration’ screen
matches the trunk type administered on far-end switch.
Look for DS1-BD or MM-DS1 errors in the hardware error log. If
present, refer to the DS1-BD (DS1 trunk Media Module) Maintenance
documentation or to the MM-DS1 (MM-DS1 trunk Media Module)
Maintenance documentation.
Retry the test at 1-minute intervals for a maximum of 5 times.
Table 125: TEST #136 DS1 Tie Trunk Seizure Test 2 of 3
Error
Code
Test
Result
Description/ Recommendation
2 of 3
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...