This is a Dial-Tone Test.
Table 71: DIOD Trunk Errors without Associated Tests
Error
Type
Aux
Data
Description and Recommendation
769
57392
CO not releasing after call is dropped from PBX. After several occurrences,
an off-board warning alarm is generated. Refer problem to CO.
2561
57345
Single polarity ringing current. This error results from abnormal ringing
current, but does not prevent the incoming call from being accepted. One
cause could be that the reverse current detector associated with the port is
failing. (Will not be detected by any tests.) The other cause could be that
normal current is not detected. In this case, neither incoming nor outgoing
calls can be completed, and the dial tone test also fails. Check for other
errors.
2817
57393
CO released the trunk at least four minutes after the PBX dropped the call.
This error code is log only and causes no other testing to occur. No alarm is
generated. Check for other errors.
3073
57376
No loop current on incoming call. The incoming destination has already
answered and no loop current has been detected. If this is a hard fault, the
dial tone test and all outgoing calls should also fail. Check for other errors.
3585
57424
No loop current on outgoing call. This error occurs on attempt to seize a
loop or ground-start trunk for an outgoing call. An error occurs if loop
current is not detected or the caller hangs up before it is detected. Busyout
the affected port, and run a Long test. If Dial Tone Test #0 passes, ignore
this error. Release the port.
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...