Avaya Communication Manager controlled maintenance
DIOD-TRK (DIOD Trunk)
Maintenance of the Avaya G350 Media Gateway
135
June 2004
Port Audit Update Test (#36)
This test sends updates of the CO port translation for all ports on the Media Module which have been
translated. The update is non-disruptive and guards against possible corruption of translation data
contained on the Media Module. No response message is expected from the Media Module once it
receives translation updates. The port translation data includes: ground or loop start trunk, tone or rotary
dialing trunk, rotary dialing inter-digit timing, network balance R/RC, and disconnect timing.
Table 73: TEST #36 Port Audit Update Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals a maximum of 5 times.
2100
ABORT
Could not allocate the necessary system resources to run the test.
FAIL
Internal system error.
Retry the command at 1-minute intervals a maximum of 5 times.
PASS
This test passed. Translation information was successfully updated on the
Media Module. User-reported troubles on this port should be investigated
by using other port tests and by examining trunk or external wiring. If the
trunk is busied out, the test does not run, but returns PASS. To verify that
the trunk is in-service:
Enter
status-command
to verify that the trunk is in-service. If the trunk
is in-service, no further action is necessary. If the trunk is out-of-service,
continue to Step 2.
Enter
release-trunk
command to put trunk back into in-service.
Retry the test command.
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...