User Manual
California Instruments
LOW VOLTAGE
This test will change the output voltage for the selected phase in the following sequence:
1. 28V System
•
18V for 15 msec.
•
Linearly increase to 22V in 85msec.
•
Stay at 22V for 75msec before returning to 28V.
2. 270V System
•
200V for 10 msec.
•
Linearly increase to 250V in 30msec.
•
Stay at 250V for 135msec before returning to 270V.
The
←
key (backspace) will terminate the test at any time.
9.8.1.8.3Abnormal Test
From the MIL704 DC MENU scroll to the ABNORMAL DC entry using the up and down cursor
keys. Press the ENTER key to select the ABNORMAL screen. The screen will appear as shown
in Figure 9-137.
Figure 9-137: Abnormal Test Screen
The Abnormal Test has the following tests:
1
OVER VOLTAGE
2
UNDER VOLTAGE
The above tests can be selected by scrolling to the highlighted selection using the up and down
cursor keys and the ENTER key to start the selected test.
OVER VOLTAGE
This test will change the output voltage for the selected phase in the following sequence:
1. 28V system:
•
50V for 50msec.
•
The voltage gradually decays with time to 31.5 volts by the following equation:
V = 31.38 + 0.93/t. for 0.05
≤
t
≤
7.758
•
Stay at 31.5V for 92.242 seconds before returning to 28V.
2. 270V system:
•
350V for 50msec.
•
The voltage gradually decays with time to 290 volts by the following equation:
V = 289.6 + 3.02/t. for 0.05
≤
t
≤
7.55
•
Stay at 290V for 92.45 seconds before returning to 270V.
246
i Series II / NSG 1007 II / iM Series II
Содержание 10002iX
Страница 4: ...User Manual Teseq 4 NSG 1007 Series II ...
Страница 48: ...User Manual California Instruments 48 i Series II NSG 1007 II iM Series II ...
Страница 53: ...User Manual California Instruments Figure 3 20 Functional Test Setup NSG 1007 Series II 53 ...
Страница 59: ...User Manual California Instruments Figure 3 26 Connection With MODE Option NSG 1007 Series II 59 ...
Страница 131: ...User Manual California Instruments Figure 5 73 Power Source Module Block Diagram NSG 1007 Series II 131 ...
Страница 134: ...User Manual California Instruments Figure 5 74 5001i Internal Layout 134 i Series II NSG 1007 II iM Series II ...
Страница 135: ...User Manual California Instruments Figure 5 75 Logic Board LED s NSG 1007 Series II 135 ...
Страница 164: ...User Manual California Instruments Figure 9 84 Voltage Modulation 164 i Series II NSG 1007 II iM Series II ...
Страница 204: ...User Manual California Instruments Figure 9 114 NSG 1007 15 208 CTS EOS3 LR3 204 i Series II NSG 1007 II iM Series II ...
Страница 205: ...User Manual California Instruments Figure 9 115 NSG 1007 15 208 3 EOS3 NSG 1007 Series II 205 ...
Страница 223: ...User Manual California Instruments Figure 9 118 Example Connections With INA 2151 NSG 1007 Series II 223 ...