User Manual
California Instruments
9.6Omni Options
9.6.1Introduction
This section contains information on the installation and operation of the Imepdance (Output
Matching Network Impedance) impedance network to be used with the Teseq
i-or iX-series of power sources.
9.6.2General Description
The Imepdance impedance network adds inductive and resistive impedance to Teseq i-or iX-
series power sources. This additional impedance brings the combined system impedance up to
the levels required of the power source for IEC 555-3 and IEC 1000-3-3 (flicker) testing.
9.6.3Specifications
9.6.3.1Input
Omni 1-18i and 3-18i
Omni 1-37i, 1-37iJ and 3-37i
Line Voltage
(user configurable)
115 VAC ±10% or
230 VAC ±10%
115 VAC ±10% or
230 VAC ±10%
Line Current
< 0.25 amps at 115 VAC input
< 0.125 amps at 230 VAC input
< 1.0 amps at 115 VAC input
< 0.5 amps at 230 VAC input
Line Frequency
47 to 63 Hz
47 to 63 Hz
Fuse Rating
0.25 amp, slow acting at 115 VAC input
0.125 amp, slow acting at 230 VAC
input
2 Amp, slow acting used for
both input ranges
9.6.3.2Output
Imepdance Type
1-18i
3-18i
1-37i and 1-37iJ
3-37i
Phases
1
3
1
3
Current max, rms.
18.5A per phase
18.5A per phase
37A per phase
37A per phase
Current in bypass
37A per phase
37A per phase
74A per phase
74A per phase
NOTE: To prevent damage to the Imepdance unit , the BYPASS mode must be
selected when the power source is operated on low output voltage range
or if currents in excess of Imepdance ratings will be drawn.
NSG 1007 Series II
219
Содержание 10002iX
Страница 4: ...User Manual Teseq 4 NSG 1007 Series II ...
Страница 48: ...User Manual California Instruments 48 i Series II NSG 1007 II iM Series II ...
Страница 53: ...User Manual California Instruments Figure 3 20 Functional Test Setup NSG 1007 Series II 53 ...
Страница 59: ...User Manual California Instruments Figure 3 26 Connection With MODE Option NSG 1007 Series II 59 ...
Страница 131: ...User Manual California Instruments Figure 5 73 Power Source Module Block Diagram NSG 1007 Series II 131 ...
Страница 134: ...User Manual California Instruments Figure 5 74 5001i Internal Layout 134 i Series II NSG 1007 II iM Series II ...
Страница 135: ...User Manual California Instruments Figure 5 75 Logic Board LED s NSG 1007 Series II 135 ...
Страница 164: ...User Manual California Instruments Figure 9 84 Voltage Modulation 164 i Series II NSG 1007 II iM Series II ...
Страница 204: ...User Manual California Instruments Figure 9 114 NSG 1007 15 208 CTS EOS3 LR3 204 i Series II NSG 1007 II iM Series II ...
Страница 205: ...User Manual California Instruments Figure 9 115 NSG 1007 15 208 3 EOS3 NSG 1007 Series II 205 ...
Страница 223: ...User Manual California Instruments Figure 9 118 Example Connections With INA 2151 NSG 1007 Series II 223 ...