User Manual
California Instruments
9.Options
9.1RTCA/DO-160 Option
The RTCA/DO-160 Option is made up of both firmware that resides in the power source and the
CIGuiSII Windows application program. The firmware covers revision D, and the GUI covers
revision E.
The user interface for each implementation is different however. The revision D tests can be
operated directly from the power source’s front panel or through the supplied GUI program. The
Revision E tests can only be operated through the GUI windows software. Thus, for Rev E use, a
Windows PC and interface is required.
Section 9.1.1 covers operation of the firmware based revision D tests.
For information regarding the operation of the DO160 revision E tests with the CIGuiSII, please
refer to the Avionics Software Manual (CI part no. 4994-971 included on CDROM). Note that
future updates of the CIGuiSII may include overlapping coverage for revision D in the software as
the CIGuiSII program is designed to support all revisions. For now, revision D has no associated
data files in the CIGuiSII but does have it’s own user interface control screen.
9.1.1Option –160: RTCA/DO160 rev D Tests (Firmware)
9.1.1.1General
The RTCA/DO-160D option is capable of performing all sections of RTCA/DO-160D, Section 16
and EUROCAE-14D / RTCA DO160D, Section 16 for the AC Source signal. A selection is made
available to specify the type of standard, and groups.
Throughout this document, Groups 1 through 3 will be used to refer to EUROCAE-14D standard.
9.1.1.2Initial Setup
Nominal parameters for the AC Power source are as follows:
Output Voltage
115V L-N or 230V L-N
Output Frequency
360 Hz to 800 Hz
Nominal parameters for the DC Power source are as follows:
Output Voltage
28V or 14V L-N
A setting outside these nominal values will disable the test and will prevent accessing to its Menu
screens. To access the test for the 230V L-N, the power source must be capable of
programming 360V.
NSG 1007 Series II
159
Содержание 10002iX
Страница 4: ...User Manual Teseq 4 NSG 1007 Series II ...
Страница 48: ...User Manual California Instruments 48 i Series II NSG 1007 II iM Series II ...
Страница 53: ...User Manual California Instruments Figure 3 20 Functional Test Setup NSG 1007 Series II 53 ...
Страница 59: ...User Manual California Instruments Figure 3 26 Connection With MODE Option NSG 1007 Series II 59 ...
Страница 131: ...User Manual California Instruments Figure 5 73 Power Source Module Block Diagram NSG 1007 Series II 131 ...
Страница 134: ...User Manual California Instruments Figure 5 74 5001i Internal Layout 134 i Series II NSG 1007 II iM Series II ...
Страница 135: ...User Manual California Instruments Figure 5 75 Logic Board LED s NSG 1007 Series II 135 ...
Страница 164: ...User Manual California Instruments Figure 9 84 Voltage Modulation 164 i Series II NSG 1007 II iM Series II ...
Страница 204: ...User Manual California Instruments Figure 9 114 NSG 1007 15 208 CTS EOS3 LR3 204 i Series II NSG 1007 II iM Series II ...
Страница 205: ...User Manual California Instruments Figure 9 115 NSG 1007 15 208 3 EOS3 NSG 1007 Series II 205 ...
Страница 223: ...User Manual California Instruments Figure 9 118 Example Connections With INA 2151 NSG 1007 Series II 223 ...