7.4.6Disassembly Procedure
Disconnect mains power to the source and
wait 10 minutes to allow the capacitors to
discharge before attempting to disassemble the unit.
Remove the top cover, unplug P7 from
the current limit board, and unplug the fan from the AC logic board connector. Then carefully
unplug the AC logic board from the AC and the DC power boards. The AC logic board can then
be lifted from the unit.
Using a 5/16 inch socket driver remove the four bolts that hold the AC power module heat sink.
There is one bolt at each corner. Carefully remove all the hardware from the unit. The AC power
module can now be unplugged from the input/output board and removed from the unit.
The DC - DC module can be unplugged by first removing the two nuts holding the clamp that
secures the heat sink to the chassis. See . Care must be taken in unplugging the two
connectors P4 and J12.
To reassemble, reverse the above procedure, taking care to ensure J12 on the DC-DC board
and J8 on the AC board are properly mated. This may entail supporting the connector from
behind with a screwdriver.
156
i Series II / NSG 1007 II / iM Series II
Содержание 10002iX
Страница 4: ...User Manual Teseq 4 NSG 1007 Series II ...
Страница 48: ...User Manual California Instruments 48 i Series II NSG 1007 II iM Series II ...
Страница 53: ...User Manual California Instruments Figure 3 20 Functional Test Setup NSG 1007 Series II 53 ...
Страница 59: ...User Manual California Instruments Figure 3 26 Connection With MODE Option NSG 1007 Series II 59 ...
Страница 131: ...User Manual California Instruments Figure 5 73 Power Source Module Block Diagram NSG 1007 Series II 131 ...
Страница 134: ...User Manual California Instruments Figure 5 74 5001i Internal Layout 134 i Series II NSG 1007 II iM Series II ...
Страница 135: ...User Manual California Instruments Figure 5 75 Logic Board LED s NSG 1007 Series II 135 ...
Страница 164: ...User Manual California Instruments Figure 9 84 Voltage Modulation 164 i Series II NSG 1007 II iM Series II ...
Страница 204: ...User Manual California Instruments Figure 9 114 NSG 1007 15 208 CTS EOS3 LR3 204 i Series II NSG 1007 II iM Series II ...
Страница 205: ...User Manual California Instruments Figure 9 115 NSG 1007 15 208 3 EOS3 NSG 1007 Series II 205 ...
Страница 223: ...User Manual California Instruments Figure 9 118 Example Connections With INA 2151 NSG 1007 Series II 223 ...