User Manual
California Instruments
9.8.1.7.4ABNORMAL TEST
From the MIL704 main menu (Figure 9-129) scroll to the ABNORMAL AC entry using the up and
down cursor keys. Press the ENTER key to select the ABNORMAL screens. The screen will
appear as shown in Figure 9-133.
Figure 9-133: Abnormal Screen
The ABNORMAL SCREEN has the following tests:
1
OVER VOLTAGE
2
UNDER VOLTAGE
3
OVER FREQUENCY
4
UNDER FREQUENCY
The above test can be selected by scrolling to the highlighted selection using the up and down
key and the ENTER key to start the selected test.
OVER VOLTAGE
This test will change the output voltage for the selected phase in the following sequence:
•
180V for 50msec.
•
The voltage gradually decays with time to 125 volt by the following equation:
V = 124.6 + 2.77/t. for 0.05
≤
t
≤
6.925
•
Stay at 125V for 93 seconds before returning to 115V.
Prior to the test, a range change may take place if the power source is set at the low voltage
range.
The
←
key (backspace) will terminate the test at any time.
Note:
A range change will result in momentary loss of power to the EUT. If this is not
acceptable, the power source must be left in high range at all times.
UNDER VOLTAGE
This test will change the output voltage for the selected phase in the following sequence:
•
0V for 7 seconds.
•
100V for 93 seconds.
•
The
←
key (backspace) will terminate the test at any time.
OVER FREQUENCY
This test will change the output frequency in the following sequence:
•
480Hz for 5 seconds.
•
420Hz for 9 seconds.
The
←
key (backspace) will terminate the test at any time.
NSG 1007 Series II
243
Содержание 10002iX
Страница 4: ...User Manual Teseq 4 NSG 1007 Series II ...
Страница 48: ...User Manual California Instruments 48 i Series II NSG 1007 II iM Series II ...
Страница 53: ...User Manual California Instruments Figure 3 20 Functional Test Setup NSG 1007 Series II 53 ...
Страница 59: ...User Manual California Instruments Figure 3 26 Connection With MODE Option NSG 1007 Series II 59 ...
Страница 131: ...User Manual California Instruments Figure 5 73 Power Source Module Block Diagram NSG 1007 Series II 131 ...
Страница 134: ...User Manual California Instruments Figure 5 74 5001i Internal Layout 134 i Series II NSG 1007 II iM Series II ...
Страница 135: ...User Manual California Instruments Figure 5 75 Logic Board LED s NSG 1007 Series II 135 ...
Страница 164: ...User Manual California Instruments Figure 9 84 Voltage Modulation 164 i Series II NSG 1007 II iM Series II ...
Страница 204: ...User Manual California Instruments Figure 9 114 NSG 1007 15 208 CTS EOS3 LR3 204 i Series II NSG 1007 II iM Series II ...
Страница 205: ...User Manual California Instruments Figure 9 115 NSG 1007 15 208 3 EOS3 NSG 1007 Series II 205 ...
Страница 223: ...User Manual California Instruments Figure 9 118 Example Connections With INA 2151 NSG 1007 Series II 223 ...