User Manual
California Instruments
Start - Class 3
Determine appropriate test
configuration
Perform 8.2.1 Test
"Harmonic combination"
Flatcurve and Overswing
Any functional
anomalies?
Any functional
anomalies?
Any functional
anomalies?
Any functional
anomalies?
Test Completed
FAIL
Record
Results
Test Completed
PASS
Record Results
Yes
Perform 8.2.2 Test
"Frequency Sweep"
Perform 8.2.4 Test
"Meister Curve"
Perform 8.2.3 Test
"Individual Harmonics/
Interharmonics"
Yes
Yes
Yes
No
No
Any functional
anomalies?
Yes
Perform 8.2.3 Test
Only table 1. Odd
non-multiple of
3 harmonics
No
No
Figure 9-109: IEC 61000-4-13 Test Flowchart Class 3
NSG 1007 Series II
193
Содержание 10002iX
Страница 4: ...User Manual Teseq 4 NSG 1007 Series II ...
Страница 48: ...User Manual California Instruments 48 i Series II NSG 1007 II iM Series II ...
Страница 53: ...User Manual California Instruments Figure 3 20 Functional Test Setup NSG 1007 Series II 53 ...
Страница 59: ...User Manual California Instruments Figure 3 26 Connection With MODE Option NSG 1007 Series II 59 ...
Страница 131: ...User Manual California Instruments Figure 5 73 Power Source Module Block Diagram NSG 1007 Series II 131 ...
Страница 134: ...User Manual California Instruments Figure 5 74 5001i Internal Layout 134 i Series II NSG 1007 II iM Series II ...
Страница 135: ...User Manual California Instruments Figure 5 75 Logic Board LED s NSG 1007 Series II 135 ...
Страница 164: ...User Manual California Instruments Figure 9 84 Voltage Modulation 164 i Series II NSG 1007 II iM Series II ...
Страница 204: ...User Manual California Instruments Figure 9 114 NSG 1007 15 208 CTS EOS3 LR3 204 i Series II NSG 1007 II iM Series II ...
Страница 205: ...User Manual California Instruments Figure 9 115 NSG 1007 15 208 3 EOS3 NSG 1007 Series II 205 ...
Страница 223: ...User Manual California Instruments Figure 9 118 Example Connections With INA 2151 NSG 1007 Series II 223 ...