User Manual
California Instruments
5.6DC-DC Power Converter
The DC-DC power converter, A3, is powered from the rectified AC input. The converter is a
PWM (pulse width modulated) full bridge type that uses IGBT’s as the power switches. The
control logic supply for the DC-DC converter is derived from the auxiliary power supply so the
DC-DC converter does not start switching until after the auxiliary power supply has started up
and comes into regulation. This feature ensures a smooth start up.
The output of the DC converter is automatically selected for 250 VDC or 500 VDC output
depending on whether the low range output (150 Vac) or high range output (300 Vac) is selected.
The 250/500 VDC range selection is made by a relay that selects one of two taps on the DC
output transformer. The converter is fully protected with input current limit and overvoltage
protection. When the output of the DC converter is up and in regulation, the LED on the
input/output board will be lit. The LED can only be seen by looking directly down between the
large storage capacitors and the input/output board. (See Figure 5-74)
5.7AC Control Logic
The main function of the control board, A4, is to generate the gate drive signals for the AC power
stage. This board also includes the circuit for the current limit and when two or three units are
operated in parallel, the load sharing circuit. (See Figure 5-77)
The signal from the oscillator is fed through a low pass filter circuit and sent to the reference
input of the error amplifier. The voltage output of the unit is differentially sensed and fed back to
the error amplifier thereby completing the control loop. The output of the error amplifier drives a
37.5 kHz pulse width modulator. The modulator output is sent to four gate drivers which drive
the IGBT’s on the AC power board after going through opto couplers that provide the necessary
isolation.
NSG 1007 Series II
133
Содержание 10002iX
Страница 4: ...User Manual Teseq 4 NSG 1007 Series II ...
Страница 48: ...User Manual California Instruments 48 i Series II NSG 1007 II iM Series II ...
Страница 53: ...User Manual California Instruments Figure 3 20 Functional Test Setup NSG 1007 Series II 53 ...
Страница 59: ...User Manual California Instruments Figure 3 26 Connection With MODE Option NSG 1007 Series II 59 ...
Страница 131: ...User Manual California Instruments Figure 5 73 Power Source Module Block Diagram NSG 1007 Series II 131 ...
Страница 134: ...User Manual California Instruments Figure 5 74 5001i Internal Layout 134 i Series II NSG 1007 II iM Series II ...
Страница 135: ...User Manual California Instruments Figure 5 75 Logic Board LED s NSG 1007 Series II 135 ...
Страница 164: ...User Manual California Instruments Figure 9 84 Voltage Modulation 164 i Series II NSG 1007 II iM Series II ...
Страница 204: ...User Manual California Instruments Figure 9 114 NSG 1007 15 208 CTS EOS3 LR3 204 i Series II NSG 1007 II iM Series II ...
Страница 205: ...User Manual California Instruments Figure 9 115 NSG 1007 15 208 3 EOS3 NSG 1007 Series II 205 ...
Страница 223: ...User Manual California Instruments Figure 9 118 Example Connections With INA 2151 NSG 1007 Series II 223 ...