User Manual
California Instruments
VOLT MIN
This test will set the voltage and frequency to levels defined by Table 9-28 for 5 minutes. The test
will be repeated for Group1 only as indicated in Table 9-28. All Groups will repeat the test using
Table 9-28 for the voltage setting and Table 9-27 for the frequency setting. The
←
key (backspace)
will terminate the test at any time.
VOLT UNDER
This test will drop the output voltage from 115 volts to 60 volts for 7 seconds.
VOLT SURGE
This test requires 180 volts output. If the power source is set at the low voltage range, the high
voltage range will be selected before the test starts. At the end of the test the AC source will be
switched back to the low range.
The output voltage will surge to 180 volts for 100 ms. followed by drop to 148 volts for 1 sec
before it returns to 115 volts. The
←
key (backspace) will terminate the test at any time.
FREQUENCY TRANSIENTS (Group 1 only)
Seq. No.
Frequency
Time
1
400
5 minutes
2
480
5 sec.
3
400
10 sec.
4
320
5 sec.
5
400
10 sec.
Table 9-29: Abnormal Frequency Transient
This test will set the voltage at 115V and will remain at this voltage through out the test. The
test will cycle the frequency three times as shown in Table 9-29. Each repeat will start from
sequence 2.
NSG 1007 Series II
171
Содержание 10002iX
Страница 4: ...User Manual Teseq 4 NSG 1007 Series II ...
Страница 48: ...User Manual California Instruments 48 i Series II NSG 1007 II iM Series II ...
Страница 53: ...User Manual California Instruments Figure 3 20 Functional Test Setup NSG 1007 Series II 53 ...
Страница 59: ...User Manual California Instruments Figure 3 26 Connection With MODE Option NSG 1007 Series II 59 ...
Страница 131: ...User Manual California Instruments Figure 5 73 Power Source Module Block Diagram NSG 1007 Series II 131 ...
Страница 134: ...User Manual California Instruments Figure 5 74 5001i Internal Layout 134 i Series II NSG 1007 II iM Series II ...
Страница 135: ...User Manual California Instruments Figure 5 75 Logic Board LED s NSG 1007 Series II 135 ...
Страница 164: ...User Manual California Instruments Figure 9 84 Voltage Modulation 164 i Series II NSG 1007 II iM Series II ...
Страница 204: ...User Manual California Instruments Figure 9 114 NSG 1007 15 208 CTS EOS3 LR3 204 i Series II NSG 1007 II iM Series II ...
Страница 205: ...User Manual California Instruments Figure 9 115 NSG 1007 15 208 3 EOS3 NSG 1007 Series II 205 ...
Страница 223: ...User Manual California Instruments Figure 9 118 Example Connections With INA 2151 NSG 1007 Series II 223 ...