User Manual
California Instruments
This test will change the output frequency in the following sequence:
•
393Hz for 1 minute.
•
407Hz for 1 minute.
•
400Hz for 1 minute.
The
←
key (backspace) will terminate the test at any time.
VOLT UNBALANCE
This test will change the output voltage for the selected phase only in the following sequence:
•
112V for 1 minute.
•
118V for 1 minute.
•
115V for 1 minute.
The test will be repeated on three phase systems to include all three phases if the coupling is set
to all.
The
←
key (backspace) will terminate the test at any time.
PHASE DIFFERENCE
This test applies to three phase systems only. The phase angle for the selected phase will
change relative to phase A in the following sequence:
If phase B is selected:
•
236
°
for 1 minute.
•
244
°
for 1 minute.
•
240
°
for 1 minute.
If phase C is selected:
•
116
°
for 1 minute.
•
124
°
for 1 minute.
•
120
°
for 1 minute
VOLTAGE MODULATION
This test will vary the output voltage by
±
2.5V rms over a period of one second. The test will last
for 2 minutes. The
←
key (backspace) will terminate the test at any time.
FREQUENCY MODULATION
This test will vary the output frequency by
±
4Hz over a period of one minute. The test will last for
4 minutes. The
←
key (backspace) will terminate the test at any time.
WAVEFORM DISTORTION
This test will generate a 5% THD voltage distortion on the output voltage waveform. The
distortion is caused by using a clipped sinewave. The test will last for 1 minute. The
←
key
(backspace) will terminate the test at any time.
240
i Series II / NSG 1007 II / iM Series II
Содержание 10002iX
Страница 4: ...User Manual Teseq 4 NSG 1007 Series II ...
Страница 48: ...User Manual California Instruments 48 i Series II NSG 1007 II iM Series II ...
Страница 53: ...User Manual California Instruments Figure 3 20 Functional Test Setup NSG 1007 Series II 53 ...
Страница 59: ...User Manual California Instruments Figure 3 26 Connection With MODE Option NSG 1007 Series II 59 ...
Страница 131: ...User Manual California Instruments Figure 5 73 Power Source Module Block Diagram NSG 1007 Series II 131 ...
Страница 134: ...User Manual California Instruments Figure 5 74 5001i Internal Layout 134 i Series II NSG 1007 II iM Series II ...
Страница 135: ...User Manual California Instruments Figure 5 75 Logic Board LED s NSG 1007 Series II 135 ...
Страница 164: ...User Manual California Instruments Figure 9 84 Voltage Modulation 164 i Series II NSG 1007 II iM Series II ...
Страница 204: ...User Manual California Instruments Figure 9 114 NSG 1007 15 208 CTS EOS3 LR3 204 i Series II NSG 1007 II iM Series II ...
Страница 205: ...User Manual California Instruments Figure 9 115 NSG 1007 15 208 3 EOS3 NSG 1007 Series II 205 ...
Страница 223: ...User Manual California Instruments Figure 9 118 Example Connections With INA 2151 NSG 1007 Series II 223 ...