User Manual
California Instruments
T1
0 Volt
F1
F2
T2
T3
Test no.
21(I)
22(II)
23(III)
24(IV)
25(V)
26(VI)
T1 (ms)
50
50
100
100
200
200
F1 (Hz)
360
Fmax
360
Fmax
360
Fmax
F2 (Hz)
Fmax
360
Fmax
360
Fmax
360
Fmax = 650 Hz for Group 2
Fmax = 800 Hz for Group 3
T2 = 20 msec
T3 = 5 msec
Figure 9-87: Power Interrupt for Group 2 and 3
VOLTAGE SURGE
This test requires 160 volts output. If the power source is set at the low voltage range, the high
voltage range will be selected before the test starts. At the end of the test, the power source will
be switched back to the low range automatically
Voltage
Time
Seq. No.
RTCA
Group 1
Group 2
Group 3
ALL
1
115
115
115
115
5 Minute
2
160
160
160
170
30msec
3
115
115
115
115
5 Sec.
4
60
70
70
70
30msec
5
115
115
115
115
5 Sec.
Table 9-21: Normal VoltageSurge Sequence
The output voltage will follow the sequence in Table 9-21. The above sequence will repeat itself
three times. Each repeat will start from sequence two. US and Group 1 will run at 400 Hz.
Group 2 and Group 3 will run at 360 Hz and 650 Hz for Group 2 and 800 Hz for Group 3. The
frequency will return to the nominal setting when the test is completed. The
←
key (backspace)
will terminate the test at any time.
NSG 1007 Series II
167
Содержание 10002iX
Страница 4: ...User Manual Teseq 4 NSG 1007 Series II ...
Страница 48: ...User Manual California Instruments 48 i Series II NSG 1007 II iM Series II ...
Страница 53: ...User Manual California Instruments Figure 3 20 Functional Test Setup NSG 1007 Series II 53 ...
Страница 59: ...User Manual California Instruments Figure 3 26 Connection With MODE Option NSG 1007 Series II 59 ...
Страница 131: ...User Manual California Instruments Figure 5 73 Power Source Module Block Diagram NSG 1007 Series II 131 ...
Страница 134: ...User Manual California Instruments Figure 5 74 5001i Internal Layout 134 i Series II NSG 1007 II iM Series II ...
Страница 135: ...User Manual California Instruments Figure 5 75 Logic Board LED s NSG 1007 Series II 135 ...
Страница 164: ...User Manual California Instruments Figure 9 84 Voltage Modulation 164 i Series II NSG 1007 II iM Series II ...
Страница 204: ...User Manual California Instruments Figure 9 114 NSG 1007 15 208 CTS EOS3 LR3 204 i Series II NSG 1007 II iM Series II ...
Страница 205: ...User Manual California Instruments Figure 9 115 NSG 1007 15 208 3 EOS3 NSG 1007 Series II 205 ...
Страница 223: ...User Manual California Instruments Figure 9 118 Example Connections With INA 2151 NSG 1007 Series II 223 ...