75
RESISTANCE (Fan Motor
Connector)
1. Set the meter selector to the OHMS position.
2. Connect the red tester lead to the red wire; then con-
nect the black tester lead to the black wire.
3. The meter must show less than 1 ohm.
NOTE: If the meter shows more than 1 ohm of resis-
tance, troubleshoot or replace the switch/component,
the connector, or the switch wiring harness.
NOTE: To determine if the fan motor is good, connect
the blue wire from the fan connector to the positive side
of a 12 volt DC power supply; then connect the black
wire from the fan connector to the negative side. The
fan should operate.
Fuse Block/Power
Distribution Module
The fuses are located in a power distribution module in
front of the steering post. In addition, there is a 30 amp
fuse on the starter relay under the seat next to the battery.
If there is any type of electrical system failure, always
check the fuses first.
NOTE: To remove a fuse, compress the locking tabs
on either side of the fuse case and lift out.
2411-565
KC210A
NOTE: The ignition switch must be in the LIGHTS
position.
1. Remove all fuses from the distribution module.
2. Set the meter selector to the DC Voltage position.
3. Connect the black tester lead to ground.
4. Using the red tester lead, contact each end of the fuse
holder connector terminals individually.
5. The meter must show battery voltage from one side
of the connector terminal ends.
NOTE: Battery voltage will be indicated from only
one side of the fuse holder connector terminal; the
other side will show no voltage.
NOTE: When testing the HI fuse holder, the head-
light dimmer switch must be in the HI position; when
testing the LIGHTS fuse holder, the headlight dimmer
switch can be in either position.
NOTE: If the meter shows no battery voltage, trou-
bleshoot the battery, switches, distribution module,
or the main wiring harness.
1. Set the meter selector to the OHMS position.
2. Connect the red tester lead to one spade end of the
fuse; then connect the black tester lead to the other
spade end.
3. The meter must show less than 1 ohm resistance. If
the meter reads open, replace the fuse.
NOTE: Make sure the fuses are returned to their
proper position according to amperage. Refer to the
fuse block cover for fuse placement.
RELAYS
The relays are identical plug-in type located on the power
distribution module. Relay function can be checked by
switching relay positions. The relays are interchangeable.
NOTE: The module and wiring harness are not a
serviceable component and must be replaced as an
assembly.
Ignition Coil
The ignition coil is on the electrical panel under the radi-
ator/electrical access panel.
! WARNING
Care should be taken to keep clear of the fan blades.
CAUTION
Always replace a blown fuse with a fuse of the same
type and rating.
CAUTION
Always disconnect the battery when performing resis-
tance tests to avoid damaging the multimeter.
Manual