CPS100 SERIES OPERATION MANUAL
SECTION 6:
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CPS100 Series Power Source Operation Manual
Page 90 of 231
These steps are illustrated by the four screens below.
At power on, the power source will have these values already set.
Output Relay Setting:
The power source uses an isolation relay to
connect or disconnect the load from the
output of the power source. This setting
determines how the output relay functions
when the user presses the blue _
On/Off
_
button.
When the output relay (O/P Relay) is OFF,
the output relay will close when the output
state is ON and open when the output state
is OFF. This is ‘normal’ operation for most
power sources and should be the
default
setting.
When this output relay (O/P Relay) state is ON, the relay always remains closed, regardless
of the programmed output state, i.e. even if the output state is OFF. The voltage will be set
to 0V however. Use this setting only for special applications.