CPS100 SERIES OPERATION MANUAL
SECTION 6:
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CPS100 Series Power Source Operation Manual
Page 77 of 231
The Waveform Preview soft key shows the
selected output waveform in graphical form
on the LCD display.
Press the Waveform Preview soft key to
display the currently selected waveform.
Example to the right displays the SQUARE
wave.
The same screen also allows programming of the start and stop phase angles in degrees and
voltage and frequency slew rates.
6.7.1.4 Phase Angle Programming
Start and stop phase angle settings for
enabling and disabling the output can be
controlled by setting the ON Degree and OFF
degree fields in the
More Setting
screen. The
example here shows settings of 180° for ON
and 90° for OFF.
Either setting has a range from 0.0° to
359.9°. These fields can be set to
Disable
if
no phase control is desired or needed. When
Disabled
, the output on and off will occur
immediately, regardless of phase angle.
To change these setting to
Disable
, select each field and press the ESC key. To set a degree
value, select each field and use the key pad or touch screen to enter a value and press
ENTER.