CPS100 SERIES OPERATION MANUAL
SECTION 6:
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CPS100 Series Power Source Operation Manual
Page 145 of 231
6.9.5
Test Mode
The Test Mode compares measurement
values against a user defined set of
measurement limits and shows a PASS or
FAIL result in one or more measurements are
out of range. This type of limit testing is
useful for production test applications.
Measurements include I, Iac, Idc, Ipk, Is, P,
PF, VA, CF and VAR. (current and power
related measurements.)
6.9.5.1 Limit Test Settings
To set up the Limit Test mode, press the
Test
Mode
soft key from the Output Mode menu
screen.
This will display the Test Mode setup screen
where the following high and low
measurement values can be entered:
I, Iac, Idc, Ipk, Is, P, PF, VA, CF and VAR
For each measurement, move the cursor to
the Low Limit entry and use the [0] ~ [9]
keys to enter the lower limit pass value. Then
set the upper limit pass value.
For measurements that should be excluded
from pass/fail testing, set the Switch
parameter to
Disable
.
At the bottom of the Test Mode setup
screen, enter the following times:
•
Delay Time:
Time delay
between enabling
the output of the
power source and
the start of
measurement
pass/fail testing in
seconds.
•
Test Time:
Duration of
measurement and
limit compare period.
•
Remaining Time: Time to wait after end of Test time to turn output OFF.
ENHANCED VERSION ONLY