CPS100 SERIES OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CPS100 Series Power Source Operation Manual
Page 174 of 231
8
Master Slave Operation
Overview
Two or more CPS100 power sources can be configured in one of three possible
configurations:
•
Parallel Mode Max. no of units = 4 Increases output power & current
•
Series
Max. no of units = 2 Increases output voltage
•
Three Phase
Max. no of units = 3 Delta or Wye load applications
Restrictions
The following restrictions apply and should be considered at all times:
•
DO NOT
connect units in both series and parallel mode at the same time.
•
DO NOT
connect different models in series or parallel mode. All units must be the
same model number.
•
DO NOT
exceed the number of maximum units listed above for each mode.
•
Set up all Slave units first, then set up the Master in Master/Slave configurations.
•
There can only be
ONE
Master unit in any Master/Slave configuration.
•
Each Slave unit’s number
MUST
be unique or the Master/Slave mode cannot be set.
Setting up a Unit as a Slave
Multi-unit configurations require the use of
one or more Slaves. The first step to
configuring a multi-unit system is to set up
one more slave units. This done from the
MAIN menu
Press the
Parallel / Series / 3-Phase
soft key
to display the multi-unit menu.