External Input Control Mode Commands
The External Input commands control the operation of external I/O functions.
Command
Description
EXTERN:CONTROLMETHOD:_<nr2>
Sets the external control mode for the analog input.
Available modes <nr2> are:
0 Amplifier Mode
1 Level Mode
2 Voltage Set Mode
Returns OK or FALSE
EXTERN:CONTROLMETHOD?
This command queries the external control mode setting.
Return values are:
0 Amplifier Mode
1 Level Mode
2 Voltage Set Mode
Returns OK or FALSE
EXTERN:VOLTAGE:_<nr2>
This command sets the input scaling for the analog input.
Available settings are:
3 3 Volt full scale
5 5 Volt full scale
10 10 Volt full scale
Returns OK or FALSE
EXTERN:VOLTAGE?
This command queries the input scale setting. Return
values are:
3, 5 or 10
Table 7-15: External Input Commands