CPS100 SERIES OPERATION MANUAL
SECTION 4: TECHNICAL SPECIFICATIONS
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CPS100 Series Power Source Operation Manual
Page 37 of 231
ENHANCED Versions - Additional Specifications
ENHANCED MODEL FUNCTIONS
PROGRAMMABLE OUTPUT IMPEDANCE
Range
Resistance
0
Ω
- 1
Ω
Inductance
0
µ
H - 1 mH
HARMONICS & INTER HARMONICS
Range
0.01 Hz - 2400 Hz
Waveform Synthesis
2 - 40 Harmonics @ 50 Hz or 60 Hz
HARMONIC & THD MEASUREMENTS
Parameters
Voltage, Current
Harmonic Measurements
2 - 40 Harmonics @ 50Hz or 60 Hz
THD %
Calculated
IEC 61000-4 TEST FUNCTIONS
Supported Standards
IEC 61000-4-11, IEC 61000-4-13, IEC 61000-4-14, IEC 61000-4-28
Other Test Functions
Triac Waveform Test
Remote Control Interfaces
The CPS100 Series supports several standard digital control interfaces. Some of these may
be optional on certain models.
4.11.1
RS232 Interface
RS232 Interface
Connector Type
DB9
Connector Location
Rear Panel
Baud Rates
9600, 19022, 38400, 57600, 115200
Parity Bits
NONE, ODD, EVEN
Stop Bits
1 or 2
ENHANCED VERSION ONLY