Ethernet Settings
From the Remote Control screen, press the
Ethernet Setting
soft key to change LAN
interface settings. Scroll to the “ETH Setting” field and use the shuttle to set DCHP mode
(Auto) or use Manual to assign a fixed IP address. For additional information on LAN
communications, refer to section 10, “LAN Interface Configuration” on page 196.
Press the [Esc] key when done to back up to the Remote Control screen.
Parameter ranges are:
•
ETH Setting:
Auto, Manual
Note:
Presently, Auto mode is
NOT SUPPORTED
•
IP Address:
0 ~ 255
•
Net Mask:
0 ~ 255
•
Gate Way:
1 ~ 254
The factory default Ethernet setting values are:
ETH Setting = Manual
IP Address =
192.168.001.100
Net Mark =
255. 255. 255.000
Gate Way =
192.168.001.001
Socket =
2001
6.8.1.2 System Settings
The System setting screen is used to
configure the following resources of the
power source:
•
Buzzer
•
P/O State
•
O/P Relay