CPS100 SERIES OPERATION MANUAL
SECTION 5:
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CPS100 Series Power Source Operation Manual
Page 60 of 231
5.10.3
USB Interface
The USB interface provides a virtual COM port for the PC. Via this port, the unit
can be controlled as a normal RS232 interface, e.g. with a terminal program or
user application program.
Refer to the section 9, “USB Driver Installation” for further setup and
configuration information.
5.10.4
LAN Interface (Option on CPS106, CPS110 & CPS115)
The power source can be ordered with a LAN (Ethernet) interface. The LAN
interface option is located on the rear panel.
The Ethernet port is for use with a standard CAT-5 Ethernet cable and may be
connected to any Ethernet network or directly to a PC’s Ethernet port. The
Ethernet interface provides all of the control functions of the standard RS-232 and USB
interfaces. Refer to section 10, “LAN Interface Configuration” on page 196 for network and
port configuration setup information.
The default settings for the Ethernet interface are as follows:
Parameter
Default Values
ETH Setting
Manual
IP Address
192.168.001.100
Network Mask
255.255.255.000
Gateway Mask
192.168.001.001
Socket
2001
LAN interface settings can be configured from the “
CONFIG MENU”
by selecting “
Remote
Control”
, then “
Ethernet Setting
”. See section 6.8.1.1, “Remote Control” on page 85 for
details.