The following parameters are available to
define the inter-harmonic component:
•
F start Start frequency
•
F end End frequency
•
Level Amplitude in % of nVac
•
Time Time duration from F start to
Fend
•
nVac Fundamental voltage
•
nF
Fundamental frequency
Use the cursor keys or touch screen to set the inter-harmonics and fundamental parameters
to create the desired inter-harmonic frequency sweep. When done, press the
Save
soft key
to save this setting to non-volatile memory.
Note:
If the inter-harmonic setting is not saved, it will be lost when the power source is
turned off.
The output the inter-harmonic sweep, press
the [Esc] key to return to the previous
screen.
Next, press the
Trigger
soft key to start the
sweep. Once pressed, it changes to Stop.
After the Time duration expires – in this
example 10 seconds - the output will revert
to the prior steady state setting and the
Stop
soft key reverts to
Trigger
.
The sweep can be aborted if needed by
pressing the
Stop
soft key.