IEC 4-13 Sweep in Frequency Test
From the top level IEC 4-13 menu, press the
Sweep in Frequency
soft key to display the
Sweep in Frequency test screen.
Available soft keys in this screen are
Trigger
and
Edit
. Press the
Edit
soft key to set the
required test selections for this test.
There are three standard product classes for
the IEC 61000-4-13. They are Class 1, Class 2
and Class 3. (Standard modes) Test levels and
durations for these product classes are
defined by the IEC 61000-4-13 standard.
There is also a User class, which allows
parameters to be changed. (User mode).
To select the appropriate product class for
the unit under test, move the cursor to the
“Level =” field and press [Enter]. A drop
down list with product class selections is
displayed.