26.3.1.3
Fader Control Modules (FCM)
The Fader Control Module (FCM) is a circuit board that controls up to eight fader
modules and eight 1068L Input modules. It is mounted directly beneath the
faders. Its job is control of automation functions for faders and 1068 modules and
to communicate with the ACM.
The FCM plays no role in the recall system.
FCMs are controlled by the Automation Control Module (ACM). If a FCM fails,
most parts of the fader and input modules under its control will stop working.
However, the audio paths will continue to operate. No mix data is stored in the
FCM, so a FCM failure will not cause any loss of data.
FCMs are programmed using a firmware file that can be updated as needed. FCMs
can be updated and calibrated by selecting “Manage FCMs…” from the Setup Menu
in the Main window. The current FCM firmware version can be viewed in the
“Manage FCMs” window and on the VCP. See section 28.0 System Setup,
Maintenance, and Updates for detailed information on FCM management.
26.3.1.4
Fader Modules
CHANNEL FADERS
Fader modules contain four (4) sets of controls that are part of the automation
system:
The Fader Module contains the Fader and mute for the Fader 1 audio
path. It also contains the controls and indicator lights for the
Automation functions for the entire channel strip.
Fader Modules are connected to the ACM via the Fader Control Module
(FCM), which is mounted directly below them.
Fader 1: Primary volume control for the Fader 1 audio path
Fader Cap: Every fader cap is touch-sensitive and can serve as a
trigger for various automation functions (such as switching from
playback to record in Update mode )
Fader NULL Indicators: Up and down indicators that show the
offset between the written automation data and the physical
fader position.
Indicates the fader is below the written data…move the fader
“up” to match positions
Indicates the fader is above the written data…move the fader
“down” to match positions
Содержание 7-22-10
Страница 30: ...3 5 1068L Input Module ...
Страница 146: ...The diagram below indicates which 1068L parameters are controlled by the automation or recall system ...
Страница 232: ...The diagram below indicates which 1068L parameters are controlled by the automation and recall systems ...
Страница 283: ...Use the up and down arrow buttons to open the second page Press the No Cancel button to return to the Main Menu ...
Страница 339: ......
Страница 375: ......