11.3
Solo: Normal and Solo: Groups
In addition to the normal solo functions provided by the console, two alternate solo functions
are provided by the automation system:
•
Solo: Normal: Mute switches activate a solo-in-place function console-wide
•
Solo: Groups: Mute switches activate a solo-in-place function within established groups
Since the Program and Group Master Faders do not have SOLO switches, Solo: Normal and
Solo: Groups can be used to activate a solo-in-place function from these faders.
Solo: Normal and Solo: Groups can be activated via the ACM Solo Menu or the Global Functions
window in the PC software.
When Solo: Normal is active, MUTE buttons become SOLO buttons. When a MUTE button is
pressed, that channel will unmute if it was muted, and all other channels will mute. When
another mute button, is pressed that channel will also unmute and the first channel will remain
unmuted. The solo function is additive, not exclusive.
Changes to mutes made with Solo: Normal engaged are not recorded to automation.
LATCH (Latch): Activates the Latch solo activation mode
•
Only one SOLO button may be engaged at once
•
A SOLO button will remain engaged when pressed and released
•
The engaged SOLO button will be disengaged by pressing a it second time
•
Pressing a second SOLO button while one is already engaged will disengage
the active SOLO button and engage the second one
•
The solo function will be deactivated when all SOLO buttons have been
released
•
Illuminates in yellow when engaged
MIX OVER (Mix Over): Activates the Mix Over Solo mode
•
Illuminates in green when engaged
MIX OVER SOLO: Sets the level of the active Control Room Monitor source when
an AFL or PFL solo is activated
•
MIX OVER button must be engaged
Solo: Normal: Replaces the function of the MUTE
buttons with an additive solo-in-place function console
wide
•
To activate the Solo: Normal mode:
o
Select Solo: Normal from the Solo
submenu in the ACM
o
Click the Solo: Normal button in the Global
Functions window in the PC software
•
When Solo: Normal is engaged:
o
“SN” will appear VCP main display
o
The Solo: Normal button in the Global
Functions window will illuminate in yellow
Содержание 7-22-10
Страница 30: ...3 5 1068L Input Module ...
Страница 146: ...The diagram below indicates which 1068L parameters are controlled by the automation or recall system ...
Страница 232: ...The diagram below indicates which 1068L parameters are controlled by the automation and recall systems ...
Страница 283: ...Use the up and down arrow buttons to open the second page Press the No Cancel button to return to the Main Menu ...
Страница 339: ......
Страница 375: ......