Note: There is no “undo” for clearing recall settings, so it is suggested that a snapshot is
taken before the settings are cleared.
24.1.8 Read
Console
Note: Clicking the Read Console button will replace the settings in the Recall Settings
window with the current settings from the console.
24.2 Recall System Procedures
For all procedures below:
1.
Open a Vision Project File using the “File” menu in the Main window.
2.
Open the “Project” window using the “View” menu in the Main window.
3.
Click the Snapshot Tab in the Project Window
4.
Open the “Recall Settings” window using the “View” menu in the Main window.
24.2.1 Making Software Channel Output Assignments and Recallable Switch Settings
To make channel output assignments and to set recallable switches using the recall
system, perform the following procedure:
1.
Make sure any needed console settings have been stored in a snapshot before
changing the settings in the Recall Settings Window. (See 23.6.1 Taking a New
Snapshot)
2.
Select the desired channel(s) in the Channel Grid.
3.
Check the desired output assignments and switch settings.
4.
The output assignments will be shown on the Channel Assignment Displays and the
selected recallable switches will be set
Read Console: Reads the current output assignments and recallable
switch settings from the console and updates the Recall Settings
window.
When the “Read Console” button is clicked, the recall system will
“Read” the current states of the recall settings from the console. These
settings can then be stored as part of a snapshot.
Содержание 7-22-10
Страница 30: ...3 5 1068L Input Module ...
Страница 146: ...The diagram below indicates which 1068L parameters are controlled by the automation or recall system ...
Страница 232: ...The diagram below indicates which 1068L parameters are controlled by the automation and recall systems ...
Страница 283: ...Use the up and down arrow buttons to open the second page Press the No Cancel button to return to the Main Menu ...
Страница 339: ......
Страница 375: ......