1.2.1.1
Upper 200 Slots
The Upper 200 Slot is used for either input preamplification or channel signal
processing. The Upper 200 Slot may be fitted with the following API 200 Series
modules:
•
205L Direct Input
•
212L Microphone Preamplifier
•
215L Sweep Filter
•
225L Compressor/Limiter
•
235L Noise Gate/Expander
When the Upper Slot is fitted with a 205L or 212L to serve as a channel preamp, it
is programmed internally to feed the 1068L Input module MIC input.
The channel preamp will typically be installed in the Options Bucket when the
Upper 200 Slot is fitted with a signal processor (215L, 225L, or 235L).
For signal processing, the Upper and Lower Slots are grouped together. Internal
links may be programmed to route both slots to one of the following fixed
locations:
•
Fader 1, Pre EQ
•
Fader 1, Post EQ
•
Fader 2, Pre EQ
•
Fader 2, Post EQ
As an alternative, a USER button in the Center Section can be programmed to
switch the Upper 200 Slot to an alternate location. This is a custom option and
may not be programmed on all consoles. Refer to the studio engineering
documents and staff for details on specific installations
If the Upper 200 Slot used with for signal processing, the upper slot is located
before the lower slot in the signal flow.
NOTE: See section 3.8 200 Slot Programming and Patching for details on 200
Slot routing.
1.2.1.2
Lower 200 Slots
The Lower 200 Slot is typically used only for channel signal processing. The
Lower 200 Slot may be fitted with the following API 200 Series modules:
•
215L Sweep Filter
•
225L Compressor/Limiter
•
235L Noise Gate/Expander
For signal processing, the Upper and Lower Slots are grouped together. Internal
links may be programmed to route both slots to one of the following fixed
locations:
•
Fader 1, Pre EQ
•
Fader 1, Post EQ
•
Fader 2, Pre EQ
•
Fader 2, Post EQ
The Lower 200 Slot will remain in this fixed location determined by the internal
link and cannot be moved.
If the Upper 200 Slot used with for signal processing, the upper slot is located
before the lower slot in the signal flow.
NOTE: See section 3.8 200 Slot Programming and Patching for details on 200
Slot routing.
Содержание 7-22-10
Страница 30: ...3 5 1068L Input Module ...
Страница 146: ...The diagram below indicates which 1068L parameters are controlled by the automation or recall system ...
Страница 232: ...The diagram below indicates which 1068L parameters are controlled by the automation and recall systems ...
Страница 283: ...Use the up and down arrow buttons to open the second page Press the No Cancel button to return to the Main Menu ...
Страница 339: ......
Страница 375: ......