5-27
container Commands
For UNIX, the RAID-5 set is always scrubbed.
/wait{=boolean}
Specifies whether the command prompt returns only after the
parity-protect operation completes. If you set this switch to
TRUE
, the command prompt returns only after the RAID-5 set
is parity-protected. The scrub or zero action completes.
The default is
FALSE
;
the command prompt returns
immediately before the parity-protect operation completes.
Examples
The following example creates a RAID-5 set with the following
characteristics:
■
Creates the RAID-5 set on four disk drives connected to
channel 0
■
Specifies a freespace of 10 MB
■
Uses the scrub method
■
Indicates the command prompt return only after the scrub
operation completes
■
Specifies a stripe size of 64 KB
■
Accepts the default label