5-91
container Commands
AAC0>container remove global_failover (1,2,0)
Executing: container remove global_failover (CHANNEL=1,ID=2,LUN=0)
Use the
container show failover
command after removing a
failover disk from an array’s failover disk list with the
container
remove failover
command to display information about the
array’s failover disk list, as in the following example:
AAC0>container show failover
Executing: container show failover
container Scsi C:ID:L
--------- ----------------------------------
GLOBAL
1:03:0
0
--- No Devices Assigned ---
As the display shows, SCSI device (1,2,0) is no longer in the failover
disk list for all arrays. However, SCSI device (1,3,0) remains in the
failover disk list for all arrays.
Related Information
container
commands:
■
container set failover
(
page 5-100
)
■
container set global_failover
(
page 5-102
)
■
container show failover
(
page 5-112
)