Configuration
79
Type
Explanation
Can be assigned
to partitions
A/C fault
The output is activated when the alarm panel does not
have voltage OR any zone with type "Ext PSU A/C fault"
is triggered.
The delay until this output is activated depends on the
value set under "System -> A/C Fault Delay (minutes)".
Note
The system is VdS
compliant
if you use this output type
for signalling an
AC fault
.
No
Ext PSU Fault
The output is activated when an external power supply de-
tects a fault and reports the fault using zone type "Ext
PSU Fault".
The output is only deactivated when the fault is corrected
and the user confirms the alarm with a valid code on the
alarm panel.
No
Ext PSU Low Volts
The output is activated when an external power supply de-
tects a correspondingly low voltage using zone type "Ext
PSU Low Volts".
The alarm panel deactivates the output as soon as the
zone is reset and the user confirms the fault with a valid
code.
No
General Fault
The output is activated as soon as an event occurs that
causes a fault.
This includes:
RF Low Battery
RF Supervision
RF Jamming
A/C fault
Battery Fault
Ext PSU Fault
Tamper Activated
Note that in the event of an A/C Fault the output is already
activated a few seconds after the fault is detected and is
NOT influenced by the set delay time.
Danger
The system is
no
longer VdS compliant if you use this
output type to signal an
AC Fault
.
Use this to signal an
AC Fault
type to be VdS compliant.
Yes
Fault comm. path
The output is activated as soon as the alarm panel identi-
fies a fault in the communication method and is deac-
tivated when the fault no longer exists.
No
Full Set Ready
This output is activated when the partition is ready to be
armed.
Yes
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......