![background image](http://html1.mh-extra.com/html/abus/secvest-fuaa50-series/secvest-fuaa50-series_installer-manual_3707629289.webp)
Appendix
289
Table 4 SIA report groups
– SIA codes
SIA report group
SIA code
Contains:
Fire
FA, FR
Fire Alarm and Fire Restore
Panic alarm
HA, HR
Duress and Restore
Panic alarm
HV
Hold Up (Panic) alarm acknowledged
Panic alarm
PA, PR
Hold Up zone (Panic) and Restore
Hold Up keypad (Panic) and Restore
Hold Up RF (Panic) and Restore
Hold Up wireless control panel (Panic) and Restore
Medical Alarm
MA; MH
Medical alarm and Restore
Medical Alarm
QA, QH
Social Care (Social Emergency)
Intruder alarm
BA, BR
Intrusion Alarm and Intrusion Restore
Intruder alarm
BC
Alarm Abort
Intruder alarm
BV
Alarm confirmation
Technical Alarm
UA, UR
Technical alarm and Restore
Tampers
Yes
4 incorrect User Codes entered one after the other (also known as "User
Code Tampering")
Tampers
TA, TR
Keypad tampering and Restore
Detector tampering and Restore
Alarm control panel housing front tampering and Restore
Bell tampering and Restore
Wireless control panel tampering and Restore
External Sirens tampering and Restore
WAM tampering and Restore
Control panel tampering and Restore
Door Lock tampering and Restore
Set/Unset
CE
Schedule arming delayed
Set/Unset
CL, OP
System or partition armed and disarmed
Set/Unset
CS, OS
System or partition armed and disarmed with key switch
Part set
CL
System or partition armed internally
Part set
CS
System or partition armed internally with key switch
Reset
OR
System or partition reset
Exit Timeout
EA
Exit Timeout and Restore
Omit
BB, BU
User/system zone hidden, zone shown
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......