Configuration
78
Type
Explanation
Can be assigned
to partitions
Alarm Abort
The output is activated when an alarm is interrupted by
the user in the selected partition during the possible time
period. The output is deactivated as soon as the alarm is
confirmed.
Yes
Medical Alarm
This output is activated when a medical emergency call is
triggered.
Yes
Nursing emergency call
This output is activated when a social care call is trig-
gered.
Yes
Tamper Activated
The output is activated when the alarm panel receives a
tamper alarm from one of the following devices:
Alarm panel (cover or wall tampering)
Control device (cover or wall tampering)
Zone with zone type "Tamper"
All wireless detectors or WAM
Sirens
The alarm panel deactivates the output as soon as the
cause of tampering has been corrected.
Yes
Radio frequency failure
This output is activated as soon as one of the three RF
faults listed below occur:
This may be the following: RF Low Battery, RF Supervi-
sion, RF Jamming. The output is deactivated only when
the fault is reset on the alarm panel.
Yes
RF Supervision
This output is activated as soon as any wireless zone re-
ports a monitoring failure (supervision fault).
The output remains activated until all supervision faults
have stopped.
Yes
RF Jamming
The corresponding output is activated when signal jam-
ming is detected.
The output remains activated until the signal jamming is
corrected.
No
RF Low Battery
The output is activated as soon as a wireless detector
sends a low battery message.
The output remains activated until all detectors no longer
send this message.
Yes
Battery Fault
The output is activated when the alarm panel identifies a
fault with the backup battery OR a zone with zone type
"Ext PSU Batt Fault" is triggered.
If the alarm is triggered by a zone with "Ext PSU Batt
Fault" the alarm panel only deactivates the output when
the zone itself is reset and the user confirms the fault with
a valid code on the alarm panel.
If the alarm is triggered by a fault with the backup battery,
the output is only deactivated again as soon as the alarm
panel detects a suitable and functioning battery.
Note: check the function of the battery using the test func-
tion available in the menu on the alarm panel.
No
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......