Configuration
138
Name/function
Explanation (checkbox)
Silence Alerts
(silent warnings)
This option controls the length of time in which warning tones (a brief "beep" every
few minutes) are sounded.
Dropdown selection field for:
User Code
Warnings are sounded until a user enters their code to confirm the warning.
30 minutes
60 minutes
120 minutes
Warnings are sounded for the set amount of time. The warning tones can be
stopped by entering a user code.
No alert tones
No acoustic alerts are sounded.
Note
The alarm panel does not display any warnings as long as a partition is still armed.
Abort time
Input field for the alarm abort time in seconds (value between 0 and 120).
The alarm panel always starts this time when an alarm has been triggered. If a user
mutes the alarm during this time, no installer reset is required.
If an alarm occurs and a user disarms the system
within
this time, "Alarm Abort"
outputs are activated and an alarm abort is reported.
Siren Delay (User)
“Siren Delay (User)” in minutes (value between 0 – 10).
0 means disarmed.
Note
When “Siren Delay (User-based)” is enabled (> 0), the entire behaviour of the siren
delay is blocked in the partition settings.
This does not comply with EN 50131.
ARC communication and Confirmation Mode affect the siren delay in the partition
settings.
Note
Siren Delay (User)
only
affects the outdoor sirens.
Note
In the event of a fire, intruder or 24h alarm, there is no siren delay (user)
Entry Alarm Delay
Additional delay when deviating from the entry route.
Select whether the user is permitted an additional time of 30 seconds when deviat-
ing from the entry route, before an external alarm is started.
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......