Appendix
296
Log
Log book entries
This appendix provides a short explanation of the messages that may appear in the alarm panel log.
Please note that many of these messages refer to specific components with the respective component numbers. For
this reason, it is not possible to show the exact log messages that you would see in a particular installation in this list.
The list itself is in alphabetical order according to the message text. In the “Log entry” column you will see “==” or
sometimes “#”. These characters stand for zone, user or component numbers which the alarm panel has recorded for
the event. In the “Explanation” column, this will be displayed as “nn” or “n”.
In the listed communication messages, “$m” stands for the type of the communication channel used.
Log book entry
Explanation
"$m Alarm OK"
Successful alarm transmission to the ARC via the corresponding transmis-
sion path (PSTN / IP / GSM / wireless mobile)
"$m Email Fail"
$m Email Fail
"$m Line Restore"
Communication channel restored
"$m Line Fault"
Communication channel fault
"$m Modem Fault"
$m modem fault
"$m Modem Restore"
$M Modem Restore
"$m fault ESCC protocol"
$m fault in communication monitoring station log
"$m Social Fail"
$M fail when sending the social care protocol
"$m SMS Fail"
$m SMS Fail communication
"$m Speech Fail"
$m Speech Dialler failed
"== A/C Fail Rst"
Extension == power supply restored
"== A/C Fail Flt"
Extension == power supply failure
"== Aux Fuse Flt"
Extension == fuse missing
"== Aux Tamper Rstr"
Extension == fuse restored
"== Aux1 O/P Flt"
Extension == power failure in output 1
"== Aux1 O/P Rst"
Extension == power in output 1 ok
"== Aux2 O/P Flt"
Extension == power failure in output 2
"== Aux2 O/P Rst"
Extension == power in output 2 ok
"== Miss Batt 1"
Extension == battery 1 missing
"== Batt 1 OK"
Extension == battery 1 ok
"== Miss Batt 2"
Extension == battery 2 missing
"== Batt 2 OK"
Extension == battery 2 ok
"== Ex Keys Rstr"
Tampering via
too many incor-
rect code en-
tries will be re-
set
"== Chargr 1 Flt"
Extension == battery 1 charger faulty
"== Chargr 1 RESTORE"
Extension == battery 1 charger ok
"== Chargr 2 FLT"
Extension == battery 2 charger faulty
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......