Configuration
133
Name/function
Explanation (checkbox)
Supervision
Dropdown selection field for alarm system response for supervision
If a wireless detector has had no contact with the alarm control panel for more than
20 min, the alarm panel creates a log entry: "RF warning". The alarm panel also
prevents the system from being armed. If a user overrides this warning and arms
the alarm panel, the log entry "RF warning overridden" is generated.
If a wireless detector has had no contact with the alarm panel for more than 2 h,
corresponding processes are activated as follows:
Alarm panel is armed
Alarm panel is disarmed
Disabled
No response
No response
Fault
Log book entry of this
event
No
display and no warning
tones
"RF Supervision" or "RF Fault"
outputs are activated
Log book entry of this event
Display and warning tones
"RF Supervision" or "RF Fault"
outputs are activated
Tamper Ac-
tivated
Tampering alarm
Supervision is reported
Note
:
If "Tamp as Tamp-Only" is disa-
bled, the "Supervision" or "Fault"
outputs are also activated.
If no tamper channel is assigned
in FF, an "unconfirmed alarm" is
sent.
Tampering alarm
Supervision is reported
Note
If "Tamp as Tamp-Only" is disa-
bled, the "Supervision" or "Fault"
outputs are also activated.
If no tamper channel is assigned
in FF, an "unconfirmed alarm" is
sent.
Note
The "Tamper" option is required in Grade 2 systems in order to comply with
EN 50131-1:2006+A1:2009.
If the "Tamper" option is used along with the following setting:
System -> User Reset -> System Tampers = No
the user cannot reset the system.
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......