Configuration
93
The main purpose of the siren delay is to give communication with the ARC time and
to be able to react from there, before the siren warns the intruder that the alarm has
been triggered.
The siren delay occurs when:
Partition -> Alarm reaction -> Siren + ESCC Reporting / Flash + ESCC Reporting
Communication ARC: yes
Confirmation -> Confirmation Mode -> Basic
Sounder On -> Confirm
Exceptions: Unconfirm see below
Siren On -> Confirm
Settings
Effect
Sounder On
Siren On
Unconfirm
Unconfirm
Unconfirmed alarm
: the internal sounders
and sirens sound
constantly
and for the entire
siren time
Confirmed alarm
: the alarm panel retriggers
the sirens and internal sounder, which then
sound for the entire
siren time
, even if this has
previously elapsed.
Unconfirm
Confirm
Unconfirmed alarm
: the internal sounders
sound constantly and for the entire
siren time.
No
external sirens
Confirmed alarm
: the alarm panel waits for a
potential
siren delay
and then starts
both the internal sounder and the external si-
rens. These both sound for the entire siren
time.
Confirm
Confirm
Unconfirmed alarm:
No sounders or sirens.
Confirmed alarm:
the alarm panel waits for a
potential
siren delay
and then starts both the
internal sounder and the external sirens.
These both sound for the entire
siren time
.
No siren delay if:
No siren delay if Unconfirm for both (factory settings). See table above.
1st The siren delay does not come into effect if the alarm reaction mode does not re-
quire any communication or if a wiring error is identified.
2. The siren delay also does not come into effect when System Options -> Confirma-
tion mode is set to DD243 or BS8243 OR System options -> Confirmation -> Sirens
On is set t
o “Unconfirm”.
3rd Sounders to which two or more partitions have been assigned use the shortest
siren delay among the partitions assigned to the sounder.
The siren delay is also prevented when System Options - Confirmation Mode is set
to Basic and Siren On
is set to “Unconfirm” (default settings). These are the default
settings for the alarm panel.
The siren delay is also prevented when the ARC communication is disarmed.
No siren delay in the case of fire alarm, panic alarm or 24h alarm.
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......