Configuration
221
Function
Meaning
Emergency buttons
Testing of the remote control is carried out in the web interface in the same manner as on the
alarm panel.
Press the button on a pendant.
The following information appears on the display
which user is assigned to this emergency button
the function of this pendant
HUA = hold up alarm
Medical = medical emergency
PFN alarm = social care alarm
the received signal strength (RSSI)
Example
User: User 002
Func: Medical
RSSI: 9
ARC reporting
Testing of the ARC reporting function is carried out in the web interface in the same manner
as on the alarm panel.
ARC Reporting must be activated and the contact must be saved in the phone book.
Installer Mode->Communications->ARC Reporting ->Call Mode ->Single
(or Alternate)
A list of the available connected transmission paths can be seen:
Ethernet, Ethernet / IP Mobile
When this is selected, the 2 possible configured recipients (IP Recipient 1, IP Recipient 2)
are displayed with their contact names as stored in the phone book.
Scroll to the desired contact. Press the "Select” or “Start” key in the web interface.
The alarm panel sends a test call to this recipient.
The event (or trigger) "Test" is sent according to the set protocol.
PSTN
When this is selected, the 2 possible configured recipients (Tel Recipient 1, Tel Recipient
2) are displayed with their contact names as stored in the phone book.
Scroll to the desired contact. Press the "Select” or “Start” key in the web interface.
The alarm panel sends a test call to this recipient.
The event (or trigger) "Test" is sent according to the set protocol.
GSM / Mobile
When this is selected, the 2 possible configured recipients (Tel Recipient 1, Tel Recipient
2) are displayed with their contact names as stored in the phone book.
Scroll to the desired contact. Press the "Select” or “Start” key in the web interface.
The alarm panel sends a test call to this recipient.
The event (or trigger) "Test" is sent according to the set protocol.
During the test call a series of progress messages appear on the display.
If the test call was not successful, the display shows a brief message with the
cause of the error.
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......