Configuration
108
Name/function
Explanation
Siren time Int. [min]
Time for the duration of the internal siren(s) in minutes after a burglar alarm.
The siren time can be set to a value between 0 and 20 min.
If sounders are assigned to multiple partitions, the alarm panel uses the longest si-
ren time set for the partitions in question.
The time for which the sounders are active can also be extended to the longest si-
ren delay for that partition.
Note
Internal sirens always sound after a fire or hold up alarm until the alarm is confirmed
by a user for safety reasons. For safety reasons there is no time limit for a fire alarm
or hold up alarm.
Special response when an entry delay is used
Requirement
The internal sounders (alarm panel, wireless indoor siren, wireless info module)
are muted again after the internal siren time has expired.
The alarm panel has automatically rearmed (see also "Installer Mode
System -
> Security
Auto Rearm").
Response
If you now enter the entrance area ("Final Door" and "Entry/Exit Follow" detectors
are opened), the internal sounders (alarm panel, wireless indoor siren, wireless
info module) emit an
alarm tone
.
The
normal entry tone
is
not signalled
in this case.
Note
When the entry delay is used, you would usually expect to hear the normal entry
tone. This entry tone should be heard as long as the entry delay is running. If you
hear an alarm tone after opening the entrance door, you know immediately that the
alarm panel has detected an intrusion during your absence.
The delay time runs anyway. Disarm the alarm panel within the delay time.
Do so
only if you feel it is safe, however. An intruder could still be inside the prop-
erty!
If you do not disarm the system, an additional burglar alarm is triggered once
the delay time has expired.
Notify others who have access to your property of this response of the alarm panel.
Endless
On
Internal sirens signal the alarm tone until an alarm is acknowledged by a user.
Off
The siren time for the duration of the internal siren(s) is used.
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......