Appendix
279
ARC/ESCC reporting
ARC/ESCC reporting protocol formats
Note:
To conform with EN50131, ARC (ESCC) reporting must be enabled.
The alarm control panel automatically uses the classic protocols if the alarm control panel uses PSTN or
GSM/wireless mobile as an outgoing communication path.
Fast Format
When using Fast Format, each message sent to the ARC (ESCC) consists of the following:
4, 5 or 6-digit account number.
8 data channels.
Each channel communicates the status of an output. The type of corresponding output (channel) is set under
the "FF Channels" menu item (see page xyz). Each channel can provide the following values:
1 = New alarm and not yet reported
2 = Output status is open/disarmed
3 = Alarm reset and not yet reported
4 = Output status is closed/enabled
5 = No alarm
6 = Alarm but reported earlier
Test signal or status
Contact ID
The Contact ID format transmits data from the log book entries to the ARC (ESCC). Examples of messages in Contact
ID format are:
Example 1
1234 18 1137 01 015 2
1234
This is the account number as specified in the Account Numbers menu item (page xyz).
18
This is the message type used to identify the message as a Contact ID
1137
This is the event identifier for a new event (1), followed by the event code for a system tamper alarm (137)
01
This is the partition number
015
This is the zone number
2
This is the checksum value that the ARC (ESCC) needs to check and confirm that a valid message has
been received
Example 2
1234 18 3137 01 015 3
The only difference between this example and the first example is the event identifier of 3 to show a restore for the
system tamper alarm and the checksum value.
SIA 1, SIA 2, SIA 3, Extended SIA 3 and Extended SIA 3 V2
The SIA formats transmit data from the log book entries to the ARC (ESCC).
The four SIA formats differ based on the data volume that is transferred with each message.
Type
Format
SIA1
#AAAAAA|NCCcc
SIA2
#AAAAAA|Nidnnn/rinn/CCcc
SIA3
#AAAAAA|Ntihh:mm/idnnn/rinn/CCcc
#AAAAAA|AS
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......