Configuration
83
Type
Explanation
Can be assigned
to partitions
User Defined
An output of this type can be controlled remotely via dif-
ferent user-defined components such as remote control,
control panel or alarm panel.
The “Switch by user” and “configure by user” options
grant the user permissions for the configuration of the out-
put in the user menu view.
The “Polarity” button can be used to invert the switching
statuses.
If the output should only be switched for a specific time
(pulse behaviour), then un-
tick the “Continuous” checkbox
and set the desired duration.
The output can also be assigned a time plan, which speci-
fies when it should be activated or deactivated. The “Con-
tinuous” checkbox must be ticked for this. Then set the
switching on time, the switching off time and select the
desired days of the week.
The output can also be switched by the occurrence of
events. On the “Events” tab, you can set up to 3 events.
The list contains all possible output types.
No
Smoke Sensor Reset
This output is always activated (0 V) except when a user
confirms a fire alarm.
After this confirmation, the alarm panel deactivates the
output for 3 seconds.
The output type is designed to facilitate interaction with
low voltage reset connections on wired smoke detectors.
Note that there are also smoke detectors common on the
market that require a second confirmation in order to be
reset (detectors that require time to reset the alarm con-
tacts after the reset pulse).
Yes
PIR Set Latch
This type requires the system or partition to have been
armed.
This output is deactivated when the system or partition is
disarmed or an alarm event occurs.
The output is activated for one second when either the
system is reset or installer mode is exited on the alarm
panel.
Note: if "Normal" polarity is selected, the output is actu-
ated with +12 V when activated and 0 V when deac-
tivated. Use the "Inverted" polarity to reverse the function
of this output.
Yes
Combination Output 1
An output of this type combines various events. Details on
this can be found in the "Combination Outputs" chapter.
…
Combination Output 10
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......