Appendix
283
Table 1 CID codes
– CID report groups
CID code
Contains:
CID report group
100
Medical alarm
Medical Alarm
101
Social Care (Social Emergency)
Medical Alarm
110
Fire Alarm and Fire Restore
Fire
120
Hold Up zone (Panic) and Restore
Hold Up (Panic) silent and Restore
Hold Up keypad (Panic) and Restore
Hold Up RF (Panic) and Restore
Hold Up wireless control panel (Panic) and Restore
Panic alarm
121
Duress Code alarm
Panic alarm
129
Hold Up (Panic) alarm acknowledged
Panic alarm
130
Intrusion Alarm and Intrusion Restore
Intruder alarm
137
Alarm control panel housing front tampering and Restore
Keypad tampering and Restore
Detector tampering and Restore
Control panel tampering and Restore
Bell tampering and Restore
Wireless control panel tampering and Restore
External Sirens tampering and Restore
WAM tampering and Restore
Door Lock tampering and Restore
Tampers
139
Alarm confirmation
Intruder alarm
150
Technical alarm and Restore
Technical Alarm
150
Key Box open and closed
Key Box
300
Fault and Restore for: Aux. 12 V, system 12 V
Faults
301
A/C mains fail and Restore
Mains Fault
302
Panel Battery flat/fault and Restore
Panel Battery
305
System or partition reset
Reset
311
Panel Battery flat/missing and Restore
Panel Battery
311
External battery fault and Restore
Faults
320
External sounder zone fault and Restore
WAM fault and Restore
Faults
337
Smoke alarm device/WAM PSU fault and Restore
RF Battery/PSU
337
External PSU fault and Restore via Zone n
Faults
338
External Siren/WAM flat battery/battery fault and Restore
RF Battery/PSU
338
External PSU low voltage via Zone n
Faults
342
External PSU AC fault and Restore
Faults
344
Jamming fault and Restore 1)
RF Jamming
351
Communication path fault and Restore
Faults
373
Smoke alarm device fault and Restore
Faults
375
Hold Up zone component fault and Restore
Faults
381
Zone supervision fault and Restore
RF Supervision
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......