Configuration
142
Only on the alarm panel
Installer Mode -> System -> Upgrade alarm panel
After pressing "Select", you will see a list of the available application software.
The first row of this list contains the currently installed software, and the other rows the available software files that are
saved on the SD card.
Example:
UPGRADE PANEL APPLICATION
V2.01.08
Installed
V2.01.08
15/06/2017
(2686976)
V2.00.00
04/10/2016
(2621440)
V1.01.00
10/02/2016
(2293760)
Select the desired application software.
Once the software has loaded, the first Start Wizard item appears (language selection). Follow the installation/Start
Wizard instructions on the alarm panel.
Important
SW >= 3.00.06, saving and restoring the configuration
Before the alarm panel starts the upgrade, the configuration files and the SSL certificate are saved automatically on
the internal flash drive. The new software is then installed, and the alarm panel restarted. At this point, the factory set-
tings are used first, but the alarm panel then automatically reproduces the configuration files and the SSL certificate
from the flash drive (as if the configuration had been saved/reproduced manually). This means that the Start wizard is
not used and the SSL certificate is not regenerated.
Checking for an upgrade?
Note
Due to conformity with EN50131, this menu at this point in Installer mode is only available directly on the alarm panel.
You will not find this menu in Installer mode when accessing via a web browser. This menu appears in the Level 4
menu. A Level 4 user must therefore log in. You will find further details in the "Software upgrade" chapter in the appen-
dix.
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......