Configuration
170
Name/function
Explanation (checkbox)
Unset Comms
Enabled
The alarm system transmits all status messages to the ARC, regardless of whether
the system is armed or disarmed.
Deactivated
The alarm system transmits tamper, network failure and other status messages to
the ARC while it is armed. When disarmed, the status messages are not transmitted
to the ARC.
Burg
Comms
Rearm
Only appears when “System
Confirmation
Confirmation Mode = Basic" and
"Communications
Protocol = Fast Format")
Enabled
The alarm system activates channel 3 again as soon as the siren time has ex-
pired. After channel 3 has been reactivated, an event can be transmitted again if it
occurs. The system automatically omits triggered zones in this case.
Note: if a "Final Door" zone is triggered, channel 3 is activated at the end of the
configured entry/exit time.
Deactivated
Channel 3 remains activated until a user or installer resets the system.
Dynamic Auto Report
Enabled
The dynamic test call is activated.
Deactivated
The dynamic test call is deactivated. The "Static Test Call" dropdown selection field
appears.
Telecoms Priority
Set the order in which the communication methods should be used here.
Ethernet / IP
Mobile
1, 2, 3 or No
PSTN
1, 2, 3 or No
GSM/mobile
1, 2, 3 or No
Note:
The alarm control panel automatically uses the IP-based protocol DC-09 if the alarm
control panel uses Ethernet (LAN) as an outgoing communication path.
In doing so, the data from traditional protocols are packed into IP packages and
transferred.
For details, see the "ARC/ESCC reporting protocols" appendix
S/W >=3.00.05
Set the order in which the communication methods should be used here.
Ethernet / IP
Mobile
1, 2, 3 or No
Note
means data transfer according to the sett
ing via IP gateway the “IP
Mobile Setup” menu
PSTN
1, 2, 3 or No
Mobile
1, 2, 3 or No
Note
means classic voice transmission (also DTMF and FSK) or SMS
transmission via a wireless mobile network.
Содержание SECVEST FUAA50 Series
Страница 12: ...Device overview 12 International key assignment...
Страница 39: ...Configuration 39 Communication...
Страница 46: ...Configuration 46 Components Teach in via web interface...
Страница 74: ...Configuration 74 Outputs...
Страница 85: ...Configuration 85 1 Select menu item Type...
Страница 94: ...Configuration 94...
Страница 111: ...Configuration 111 System...
Страница 118: ...Configuration 118 A user can reset the alarm and the General Fault outputs after entering their user code...
Страница 148: ...Configuration 148 Communication Network...
Страница 157: ...Configuration 157 ARC reporting...
Страница 159: ...Configuration 159...
Страница 177: ...Configuration 177 Voice dialler S W 3 00 05...
Страница 185: ...Configuration 185...
Страница 216: ...Configuration 216...
Страница 229: ...Configuration 229 Log S W v2 01 08...
Страница 278: ...Appendix 278...
Страница 326: ......